Selection Tables

7/8″ Bolt or dowel
Double Shear, 6mm steel internal plate to D. Fir-L glulam
Wood Member Fastener
Thickness
(mm)
Depth
(mm)
No.
of
rows
No. of fasteners in a row
2 3
Bolt spacing in a row taken as the minimum of the loaded end distance4, aL, and the spacing between bolts in a row, SR (mm)
89 133 178 222 267 89 133 178 222 267
80 190 1 0 13.6(R) 20.4(R) 27.2(R) 34.0(R) 40.8(R) 20.4(R) 30.6(R) 40.8(R) 51.0(R) 61.2(R)
80 342 2 66.675 27.2(R) 40.8(R) 54.4(R) 68.0(R) 81.5(R) 40.8(R) 61.2(R) 81.5(R) 93.4(G) 104(G)
80 342 2 111.125 27.2(R) 40.8(R) 54.4(R) 68.0(R) 81.5(R) 40.8(R) 61.2(R) 81.5(R) 102(R) 122(R)
80 342 2 125 27.2(R) 40.8(R) 54.4(R) 68.0(R) 81.5(R) 40.8(R) 61.2(R) 81.5(R) 102(R) 122(R)
130 152 1 0 23.3(R) 34.9(R) 46.6(R) 58.2(R) 65.5(d) 34.9(R) 52.4(R) 69.9(R) 87.4(R) 98.2(d)
130 266 2 66.675 46.6(R) 69.9(R) 93.2(R) 116(R) 131(d) 69.9(R) 105(R) 140(R) 160(G) 178(G)
130 266 2 111.125 46.6(R) 69.9(R) 93.2(R) 116(R) 131(d) 69.9(R) 105(R) 140(R) 175(R) 196(d)
130 266 2 125 46.6(R) 69.9(R) 93.2(R) 116(R) 131(d) 69.9(R) 105(R) 140(R) 175(R) 196(d)
130 418 3 62.5 69.9(R) 105(R) 140(R) 175(R) 196(d) 105(R) 157(R) 201(G) 219(G) 236(G)
130 418 3 62.5 69.9(R) 105(R) 140(R) 175(R) 196(d) 105(R) 157(R) 201(G) 219(G) 236(G)
175 190 1 0 32.0(R) 48.1(R) 64.1(R) 71.6(d) 71.6(d) 48.1(R) 72.1(R) 96.1(R) 107(d) 107(d)
175 266 2 66.675 64.1(R) 96.1(R) 128(R) 143(d) 143(d) 96.1(R) 144(R) 192(R) 215(d) 215(d)
175 266 2 111.125 64.1(R) 96.1(R) 128(R) 143(d) 143(d) 96.1(R) 144(R) 192(R) 215(d) 215(d)
175 266 2 125 64.1(R) 96.1(R) 128(R) 143(d) 143(d) 96.1(R) 144(R) 192(R) 215(d) 215(d)
175 380 3 62.5 96.1(R) 144(R) 192(R) 215(d) 215(d) 144(R) 216(R) 276(G) 301(G) 322(d)
175 380 3 62.5 96.1(R) 144(R) 192(R) 215(d) 215(d) 144(R) 216(R) 276(G) 301(G) 322(d)
215 266 1 0 39.8(R) 59.7(R) 77.0(d) 77.0(d) 77.0(d) 59.7(R) 89.6(R) 115(d) 115(d) 115(d)
215 266 2 66.675 79.6(R) 119(R) 154(d) 154(d) 154(d) 119(R) 179(R) 231(d) 231(d) 231(d)
215 266 2 111.125 79.6(R) 119(R) 154(d) 154(d) 154(d) 119(R) 179(R) 231(d) 231(d) 231(d)
215 266 2 125 79.6(R) 119(R) 154(d) 154(d) 154(d) 119(R) 179(R) 231(d) 231(d) 231(d)
215 342 3 62.5 119(R) 179(R) 231(d) 231(d) 231(d) 179(R) 269(R) 343(G) 346(d) 346(d)
215 342 3 62.5 119(R) 179(R) 231(d) 231(d) 231(d) 179(R) 269(R) 343(G) 346(d) 346(d)
265 342 1 0 49.5(R) 74.3(R) 83.8(d) 83.8(d) 83.8(d) 74.3(R) 111(R) 126(d) 126(d) 126(d)
265 342 2 66.675 99.0(R) 149(R) 168(d) 168(d) 168(d) 149(R) 223(R) 251(d) 251(d) 251(d)
265 342 2 111.125 99.0(R) 149(R) 168(d) 168(d) 168(d) 149(R) 223(R) 251(d) 251(d) 251(d)
265 342 2 125 99.0(R) 149(R) 168(d) 168(d) 168(d) 149(R) 223(R) 251(d) 251(d) 251(d)
265 342 3 62.5 149(R) 223(R) 251(d) 251(d) 251(d) 223(R) 334(R) 377(d) 377(d) 377(d)
265 342 3 62.5 149(R) 223(R) 251(d) 251(d) 251(d) 223(R) 334(R) 377(d) 377(d) 377(d)
315 380 1 0 59.2(R) 88.8(R) 90.5(d) 90.5(d) 90.5(d) 88.8(R) 133(R) 136(d) 136(d) 136(d)
315 380 2 66.675 118(R) 178(R) 181(d) 181(d) 181(d) 178(R) 266(R) 272(d) 272(d) 272(d)
315 380 2 111.125 118(R) 178(R) 181(d) 181(d) 181(d) 178(R) 266(R) 272(d) 272(d) 272(d)
315 380 2 125 118(R) 178(R) 181(d) 181(d) 181(d) 178(R) 266(R) 272(d) 272(d) 272(d)
315 380 3 62.5 178(R) 266(R) 272(d) 272(d) 272(d) 266(R) 400(R) 407(d) 407(d) 407(d)
315 380 3 62.5 178(R) 266(R) 272(d) 272(d) 272(d) 266(R) 400(R) 407(d) 407(d) 407(d)

Notes:

  1. The tabulated values are the minimum of the yielding resistance, row shear, group tear-out and net tension resistances of the wood member, and are applicable to tension members. For compression members, the values are conservative when the governing failure mode is indicated as group tear-out or net tension since the resistance is based on yielding and row shear only.
  2. The governing failure mode for each connection configuration is denoted either by lowercase letter (a)-(g), indicating the specific yielding failure mode as per O86 Clause 12.4.4.3.2, or by uppercase letter (R), (G) or (T), indicating failure due to row shear, group tear-out or net tension in the main member.
  3. The tabulated lateral resistances are based on removing a 10 mm thick slot to accommodate the 6 mm internal steel plate.
  4. The minimum loaded end distance, aL, is the maximum of 50 mm and 5 times the fastener diameter (O86 Clause 12.4.3.1).
  5. For the calculation of group tear-out and net tension resistances, the fastener hole diameter is assumed to be 2 mm larger than the fastener diameter.
  6. The connection resistance P'r is required to be adjusted to end-use conditions using modification factors depending on the governing failure mode as follows:
    • Pr = P'r (KD KSF KT) for yielding failure mode (a),
    • Pr = P'r for yielding failure mode (c),
    • Pr = P'r (KDy KSF KT) for yielding failure mode (d) or (g),
    • Pr = P'r (KD KSv KT) for row shear,
    • Pr = P'r (KD KSt KT) for group tear-out or net tension.

    Modification factors are provided in Section 7.4 of the Wood Design Manual 2020. For untreated wood members under standard-term loading and dry service conditions, the modification factors are 1.0.

  7. For D.Fir-L glulam, the tabulated values are valid for 24f-E, 24f-EX, 20f-E, 20f-EX or 16c-E grade. For Spruce-Pine glulam, the tabulated values are valid for 20f-E, 20f-EX or 12c-E grade.
  8. Tabulated values are based on ASTM A307 grade steel bolts or dowels, and ASTM A36/A36M grade steel plate. The resistance of steel plate needs to be checked separately.
  9. A single steel splice plate is not permitted to be used for multiple rows of bolts or dowels when the distance between the two outer rows exceeds 125 mm.
  10. N/A = not applicable.