1″ Bolt or dowel Single Shear, Hem-Fir lumber to concrete |
|||||||||||||||
Wood Member | Fastener | ||||||||||||||
Thickness (mm) |
Depth (mm) |
No. of rows |
No. of fasteners in a row | ||||||||||||
2 | 3 | ||||||||||||||
Bolt spacing in a row taken as the minimum of the loaded end distance3, aL, and the spacing between bolts in a row, SR (mm) | |||||||||||||||
102 | 152 | 203 | 254 | 305 | 102 | 152 | 203 | 254 | 305 | ||||||
38 | 140 | 1 | 0 | 6.75(R) | 10.1(R) | 13.5(R) | 16.9(R) | 20.2(R) | 10.1(R) | 15.2(R) | 20.2(R) | 25.3(R) | 30.4(R) | ||
38 | 235 | 2 | 76.2 | 13.5(R) | 18.2(G) | 21.5(G) | 24.9(G) | 28.3(G) | 18.2(G) | 23.2(G) | 28.3(G) | 33.3(G) | 38.4(G) | ||
38 | 286 | 2 | 127 | 13.5(R) | 20.2(R) | 27.0(R) | 33.3(G) | 36.7(G) | 20.2(R) | 30.4(R) | 36.7(G) | 41.7(G) | 46.8(G) | ||
89 | 140 | 1 | 0 | 15.8(R) | 23.7(R) | 31.6(R) | 39.5(R) | 41.2(d) | 23.7(R) | 35.5(R) | 47.4(R) | 59.2(R) | 61.8(d) | ||
89 | 235 | 2 | 76.2 | 31.6(R) | 42.5(G) | 50.4(G) | 58.3(G) | 66.2(G) | 42.5(G) | 54.4(G) | 66.2(G) | 78.1(G) | 89.9(G) | ||
89 | 286 | 2 | 127 | 31.6(R) | 47.4(R) | 63.2(R) | 78.0(G) | 82.5(d) | 47.4(R) | 71.1(R) | 85.9(G) | 97.7(G) | 110(G) | ||
140 | 140 | 1 | 0 | 18.6(R) | 28.0(R) | 37.3(R) | 46.6(R) | 48.3(d) | 28.0(R) | 41.9(R) | 51.6(T) | 51.6(T) | 51.6(T) | ||
140 | 241 | 2 | 76.2 | 37.3(R) | 55.9(R) | 67.4(G) | 76.7(G) | 86.0(G) | 55.9(R) | 72.1(G) | 86.0(G) | 100(G) | 114(G) | ||
140 | 292 | 2 | 127 | 37.3(R) | 55.9(R) | 74.6(R) | 93.2(R) | 96.7(d) | 55.9(R) | 83.9(R) | 112(R) | 131(G) | 145(d) | ||
Notes:
|
. |